Offices in Malta

OFFICES INMalta

SEARCH OFFICES

Office Space with Views

Ref. No: 53532

  • LOCATION: The Quad
  • Area 455 Sq metres
  • PRICE: € 3,400,000.00
  • Longlet: No
  • Property Sale: Yes
New in our offices for rent in Malta, is this commercial property forming part of a brand new development. It covers an area of 455sqm and will be finished to the highest specifications. Structural Internal core wall and columns • Gypsum Plastered and finished in emulsion paint. Main door to the unit • Fire rated with 2-hour fire rating as per architect and fire consultant specifications. Internal doors in unit • Flush doors in kitchenette and toilets cluster. Intercom • Outdoor unit intercom at office main door. Video / Colour Flooring • Reinforced concrete Structural slab. • Raised flooring system (ceramic tiles) to be installed with skirting. Ceiling • Reinforced concrete flat slab • Suspended ceiling – Demountable Grid type (Class 0, 600mm x 600mm) throughout and bulk heads where required. • The reception area and maximum 2 boardrooms will be gypsum flat ceiling. ELECTRICAL Tap-off arrangement • Bus-risers with tap-off box provided in a bus-bar chamber. Earthing system • Provided. Lightning protection system • Faraday Cage Lightning Protection System according to BS EN 62305 Electrical Power Supply • 50W/m2 Non-Essential supply for AC systems. (50 kVA/1000m2). • 25W/m2 Essential supply, on Diesel driven stand-by generator, for power and lighting. (25kVA/1000m2). • An electrical sub-meter for each office will be installed • A distribution board for essential power. • Supply to VRF units on non-essential supply. Electrical installations • Based on a population of 1 person per 12m2, provisions shall be made for a maximum of one 13A twin socket outlet per person based on an open plan office layout. Office Lighting • Lighting shall be based on an open plan layout and designed on the recommended average illuminances of 500 lux at desk level, on the horizontal working plane. • Office lighting shall be on/off type controlled by presence detectors. • Emergency lighting shall be provided with self-contained battery-operated emergency lights based on an open plan layout. ICT Installations • Provisions for receiving fibre optic supply to each office. • Based on a population of 1 person per 12 m2 in an open plan office, provisions shall be made for 1 grommet per 12m2, 1st Fix only for network outlet per workstation (2 points per person). HVAC AC system • Based on a population of 1 person per 12m2 in an open plan layout (open plan does not include WC clusters and kitchenettes), a 3-pipe VRF system (providing simultaneous cooling and heating) shall be provided in line with the engineering consultant's specifications. AC system for data room if required by tenant • One indoor air-conditioning standby unit shall be installed in the data room if applicable. The standby air-conditioning unit will be connected to the uninterrupted power supply. Ventilation • Heat recovery ventilation system (through air to air heat exchanger units). The ventilation system shall have a capacity of 13 litres per second per person and allowance of 1 person per 12m2 in an open plan layout (open plan does not include WC clusters and kitchenettes)
Office Space with Views
Office Space with Views
Office Space with Views
About the area: Malta
PRICE: € 3,400,000.00
MORE IN THIS AREA

Enquire about this property

Our team will reach out to you as soon as possible.

    About You

    About your Property